Compact 1W DC-DC Converter
With Ultra High I/O Isolation of 6000 VDC and Isolation Barrier of 2.5mm
Aimtec Inc. strengthens its 1 watt product offering with the launch of the
AM1DC-Z series of DC-DC converters providing ultra high I/O isolation of
6000 VDC with an isolation barrier of 2.5mm, providing supplemental
isolation.
Input voltages of 5, 12 and 24 VDC converts to single and dual output voltages of (±)3.3, (±) 5, (±)9, (±)12 and (±)15 VDC with continuous short circuit protection. Operating at efficiencies as high as 79% within an ambient temperature range of -40C to +71C at full load or up to +85C with derating, the AM1DC-Z series is well suited for both indoor and outdoor industrial applications including motor control, test and measurement. Designed in a compact SIP7 package (19.56 x 9.90 x 12.45mm), the AM1DC-Z ‘s I/O isolation barrier (2.5mm) meets the specifications outlined in the IEC 60950-1:2001 safety standard ITE (rated for 250VAC working voltage), allowing these converters to be used in a multitude of space critical applications. Made with high quality, RoHS compliant materials that undergo rigorous quality control to ensure reliability and performance, the AM1DC-Z series is competitively with samples available from stock for immediately delivery. |
![]() |
AM1DC-Z DC-DC Encapsulated Series
|
Status:
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]()
Input Specifications
Isolation Specifications
Output Specifications
General Specifications
NOTE: All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.5..Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||